Fully Automatic No Load ( Routine) Testing Panel For Self Priming Motors

Range : Up to 15 Amp.​

Full load testing for self priming pumps with pneumatic system for loading & unloading of pumps

Full load testing for self priming pumps with pneumatic system for loading & unloading of pumps

Aarohi introduced a fully automatic routine testing panel for Self Priming Motor. The primary purpose of the routine test is to ensure freedom from electrical and mechanical defects and to demonstrate by means of key tests the similarity of the motor to a “standard” motor of the same design.

This panel also helps to enhance productivity, Work efficiency & reduces need for skilled operators. More than 500 Indian pump manufacturer ware installed this system & satisfied with the performance.

Parameter

Description

Range

Up to 15 Amp.

Enclosure (Panel) type

Tabletop, ATM, Cupboard

Test covered

IR, HV, Locked rotor, No-load

Computer interface

Rs 485

Suitable Motor type 

1 phase up to 1 HP

Data login

Automatic data logging

Software

“ Auto tester” Client server-based software with user management for all types of a motor with real-time data monitoring & production report generation.

Indication

LED tower lamp for Pass/ Fail & test in progress status.

Protections

MCB for overload protection, Isolation transformer for auxiliary protection.

Output connections

Screwless terminals inside panel

Voltage control

Automatic though Multi tapping transformer according to master data

Mode of operation

Automatic & manual both provided

Enclosure/ Panel colour

Siemens grey

Test time

40 sec. max for above mention test.

FEATURES

BENEFIT

Automatic data logging facility

Minimize human efforts & errors

Model/ Motor wise report generation

Provide production data analytics

Client server-based software

Anyone can access easily on a network

Voltage-controlled by multi tapping transformer

Reduces testing cycle time below 40 seconds.

Aesthetic design of a panel

Create a good impression on visitors

Software with user management

Avoid unauthorised usage.

  • Test lab at motor manufacturer.
  • Repairing/ Service centers
  • Motor testing labs.
  • Lab. for educational institute.
Request for

Quote

    Instant Online Request for Quote

    Self Priming Testing Penal Brochure

    Related Products

    Automatic Stator Testing Panel

    Range : HVT: 5 KV/ 250 mA / For IR: 1000 Mohms/ 500 Vdc

    Read More

    Automatic HV/ IR test system

    Range : HVT: 5 KV/ 250 mA / For IR: 1000 Mohms/ 500 Vdc​

    Read More